A robust, precise autosampler is necessary to achieve optimal efficiency and accuracy.
Advanced fluidics technology featuring a patented injection valve that facilitates accurate and highly reproducible injections
Integrated column oven
Onboard, automated dilution and derivatization, without the use of additional hardware or software
High-visibility color LCD screen for quick and efficient review of pump pressure, oven and sample tray temperature, and sample queue status without having to log into your CDS software
Reliable GC Workflows for Every Lab
The Clarus Nova GC system enables laboratories to increase productivity and expand Gas Chromatography capabilities across environmental, petrochemical, food, and pharmaceutical applications.
With expanded gas analysis capabilities including TCD, NGA, and TOGA, laboratories can take on a wider range of gas and hydrocarbon applications. SimplicityChrom™ CDS, predictive maintenance, and tool free components help simplify operation, reduce service time, and keep laboratories productive.
Maximum Uptime and Efficiency:
Real time diagnostics, predictive maintenance alerts, and tool free components help minimize downtime and keep your laboratory running smoothly.
Flexible and Scalable Platform:
Configurable autosampler options and modular system design allow laboratories to adapt workflows and scale capabilities without adding additional instruments.
High-Throughput Performance:
A high-speed GC oven with rapid heating and cooling enables faster analysis cycles and increased sample capacity within the same schedule.
Simplified Operation:
Intuitive visual workflows, guided system notifications, and streamlined software help reduce training time and allow analysts to become productive quickly.
Reliable Sample Handling:
Integrated autosampler technologies and pressure balanced injection help ensure consistent injections and reproducible analytical results.
Seamless Integration:
Compatibility with leading chromatography data systems including OpenLab®, Empower®, and Chromeleon™ enables easy integration into existing laboratory environments.
Lower Operating Costs:
Energy efficient system design and support for alternative carrier gases help laboratories reduce operating expenses while maintaining performance.
Automated Data and Reporting:
SimplicityChrom™ software streamlines data acquisition, processing, and reporting to reduce manual documentation and improve workflow efficiency.
Regulatory Ready Workflows:
21 CFR Part 11 ready workflows, audit trails, and secure user management support regulatory compliance and audit readiness.
Future Ready Platform:
Preloaded method libraries and flexible firmware updates help laboratories stay aligned with evolving analytical standards and testing requirements.
MS™ 2400 SQ Detector: Designed for High-Throughput GC-MS
The HS 2400 M Headspace Sampler is engineered to deliver unmatched repeatability, throughput, and ease of use. Featuring pressure-balanced headspace technology and seamless integration with the Clarus Nova GC, it ensures your workflows are smarter, simpler, and more productive.
Key Features:
Holds up to 40 vials with overlapping thermostatting of 12 vials for maximum throughput
Pressure-balanced, syringeless, valveless injection system for reliable performance
Multiple operation modes: Constant, Multiple Headspace Extraction (MHE), and Progressive
Fully integrated with SimplicityChrom™ CDS software and compatibility with third-party GCs
Optional hydrogen sensor for enhanced safety and sustainability
Dual Simultaneous Injection (DSI)
Dual Simultaneous Injection enables laboratories to run two injections in parallel, increasing throughput and improving workflow flexibility. With support for dedicated sampling towers on each injector, DSI helps automate workflows while maximizing instrument utilization.
Key Features:
Run two injections simultaneously to increase sample throughput
Support dedicated autosampler towers for each injector
Enable automated workflows with minimal manual intervention
Increase daily sample capacity without adding additional GC systems
SWAFER™ Technology
SWAFER technology enables advanced column switching and flexible flow path configurations, allowing laboratories to simplify complex separations and expand analytical capabilities within a single GC platform.
Key Features:
Advanced column switching for complex separations
Flexible flow path control for diverse analytical workflows
Consolidate multiple analytical methods on a single GC system
Reliable and reproducible switching performance
Thermal Conductivity Detector (TCD)
The integrated Thermal Conductivity Detector expands gas chromatography capabilities by enabling reliable detection of permanent gases and light hydrocarbons across a wide range of applications.
Key Features:
Detect permanent gases and light hydrocarbons with reliable sensitivity
Robust detector design for stable and reproducible performance
Ideal for routine gas analysis workflows
Fully integrated with Clarus Nova GC operations
SimplicityChrom™ CDS Software
SimplicityChrom™ CDS simplifies GC operation with intuitive control, automated workflows, and secure data management that help laboratories run analyses efficiently while maintaining compliance.
Key Features:
Intuitive Interface: Faster method setup and training
Automated Workflows: Streamlined data acquisition and reporting
Regulatory Compliance: Audit trails and electronic signatures
Expanded Support: TCD, gas valves, NGA and TOGA workflows
Flexible Integration: Compatible with leading CDS platforms
Industrial: Helium in Hydrogen
Clarus Nova GC helps you accurately measure trace helium impurities in hydrogen streams using an integrated TCD with an internal gas sampling valve configuration. This compact setup delivers fast, sensitive impurity detection while supporting hydrogen quality standards used in fuel production and refueling infrastructure.
Industrial: Transformer Oil Gas Analysis
Clarus Nova GC supports transformer oil gas analysis used to monitor transformer health and detect early fault conditions. Using the automated HS 2400TM M Headspace Sampler, get reliable dissolved gas analysis while supporting ASTM D3612 Method C requirements.
Pharmaceutical
The GC platform is designed to support regulated laboratory environments, helping you maintain inspection readiness while ensuring consistent performance across instruments and sites. This makes method transfer easier and helps teams deliver reliable results from early development through routine quality control.
Environmental
Clarus Nova GC helps you generate reliable environmental data while meeting evolving regulatory and sustainability requirements. The platform supports air, water, and soil testing with trace level detection and audit ready performance, helping you deliver defensible results across monitoring programs.
With fast oven performance and flexible detector configurations, Clarus Nova enables high sample throughput and sensitive VOC and pollutant analysis, supporting environmental laboratories working under demanding compliance and reporting requirements.
Food & Beverage
From flavors and packaging gases to contaminants and spoilage indicators, food laboratories rely on GC to understand what is present in complex food matrices. Clarus Nova GC supports key workflows such as volatile compound analysis, contaminant screening, and packaging gas testing, helping you evaluate food quality and safety with confidence.
Automated headspace capabilities and flexible detector configurations make it easier to analyze diverse food products and packaging environments. Consistent performance across methods helps your laboratory maintain reliable results as testing requirements and food safety standards evolve.
Designed to tackle the challenges faced by environmental testing labs analyzing PFAS and other emerging contaminants, the QSight® 500 LC/MS/MS System provides a robust solution for handling complex matrices. By minimizing sample preparation and enabling direct injection, this advanced system simplifies workflows, reducing the time and effort needed to achieve accurate results. With unmatched robustness, the QSight 500 LC/MS/MS System significantly reduces downtime and maintenance, freeing lab personnel to focus on delivering higher throughput.
The QSight LC/MS/MS System provides the capability and confidence required to analyze the most complex food and environmental samples. With high level of sensitivity and throughput, laboratories can meet even the most stringent regulatory requirements rapidly, easily, and effectively
Sensitivity for the most demanding regulations
Easy-to-use with ready to implement methods
Patented flow-based technology that enables up to 15% more productivity
StayClean™ Source, self-cleaning design for maximum sensitivity and exceptional uptime
Laminar Flow Ion Guide™ for highly efficient field-free transmission, providing virtually no maintenance requirements
Dual Source technology gives you the capability to set ESI or APCI modes, with two independent probes for true multiplexing
Modular Simplicity™ 3Q Software to acquire, quantify, and report with flexible data viewing options and powerful remote diagnostics.